Products & Manufacturers / Controls & HVAC Equipment / Pressure Switches / LEFOO LF16 Water Pump Pressure Switch
LEFOO · MECHANICAL PRESSURE-CONTROL SWITCH FOR PUMPS

LEFOO LF16 Water Pump Pressure Switch

Mechanical pressure-control switch for pumps in the LEFOO LF16 family. The correct operating range, contact wiring and hydraulic or pneumatic installation depend on the ordered variant.

LF16WaterMechanical / control engineering

Model Identification & Key Specifications

ManufacturerLEFOO
ModelLF16
Product roleMechanical pressure-control switch for pumps
Working mediumWater
Maker-listed setting envelopeExample cut-in/out pairs: 20–40, 30–50, 40–60, 70–100 psi
Electrical switchingMotor horsepower table: 120 VAC 2 HP, 240 VAC 3 HP, 3φ 240 VAC 5 HP
Options / family variants¼-in NPT male or female process connection
Manufacturer technical sourceOriginal model source linked below
OEM specification scope: Published family data must be checked against the exact motor, process medium, selected factory pressure points and delivered model suffix. A structural maximum pressure is never automatically the allowable switching setpoint.

Manufacturer Technical Data

Pump controller cut-in/cut-out must be selected as a PAIR, not one absolute upper setpoint: original example factory 20–40 / 30–50 / 40–60 or 70–100psi options, differentials typically 15–35psi depending on family row. Original electrical table lists single phase 120VAC 2HP, 240VAC 3HP and three-phase 240VAC 5HP, which are horsepower/end-use ratings, not arbitrary switch current figures. 1/4in NPT male/female connection must match installation.

AirAlign Engineering & Selection Analysis

A pump’s minimum delivery pressure and maximum vessel rating determine the target cut-in and cut-out PAIR. Comparing only maximum pressure or the horsepower figure can result in short cycling, dry running or inadequate pressure at the highest outlet.

Correct system operation is determined by the restart threshold, stop threshold, motor electrical duty and the available pressure supply. An adjustment range does not imply every combination is approved: compare manufacturer-specified differential, pressure proof, operating medium and fitting. For motor-driven equipment, locked-rotor conditions, overload protection and cycling frequency are separately important even where a contact-current rating is published.

Installation, Compatibility & Protection

Pressure settings

Specify both cut-in and cut-out conditions for the intended equipment, and verify the manufacturer’s permitted hysteresis. Do not use proof or burst pressures as running thresholds.

Contact configuration

NO and NC contacts have different protection and restart behavior. Match the wiring schedule and motor/contactor duty, rather than relying only on voltage and ampere numbers.

Medium and threaded port

Verify actual air versus water compatibility, wetted materials, connection thread standard, sealing method and temperature of the process. The manufacturer variant must support the full application.

Component approval

A maker-hosted CE, TÜV, UL or CSA record may cover only stated models and revisions. It is not equivalent to proof of ATEX/IECEx approval or a finished installation certificate.

LF16 and LF16-1: Pump Control Selection Matrix

For automatic water pumping, the cut-in/cut-out pressure pair, the usable differential and the motor horsepower rating must be considered together. LEFOO distinguishes LF16 and LF16-1 electrical configurations; using a family name alone cannot establish suitability for the installed motor.

ConfigurationManufacturer-listed examplePractical implication
Setpoint pairing20/40, 30/50, 40/60 and 70/100 psi examplesSelect the restart and stop pressures together.
LF16 motor class2 HP at 120 VAC single-phase; 3 HP at 240 VAC single-phase; 5 HP at 240 VAC three-phaseThese are motor-class ratings for the stated conditions, not a blanket ampere rating.
LF16-1 motor classLower listed ratings for some versions (e.g., 1.5 / 2 / 3 HP by supply), with order-specific alternativesDo not assume the base LF16 motor table applies to LF16-1.
Pressure connection1/4-in male or female NPT optionsVerify thread style, seal and mechanical support.
Potable water and pressure protection: Confirm the exact process-wetted material, pump compatibility and drinking-water approvals if applicable. Pressure switches do not replace the pressure vessel’s independent protective equipment. Verify the manufacturer’s model-specific UL/UKCA/CE documents rather than transferring marks across variants.

Maker evidence: LEFOO LF16 manufacturer variant table.

Related Models & AirAlign Categories

LEFOO LF10-W Water Pump Switch · LEFOO LF17-W Water Pump Switch · Pressure Switches · LEFOO manufacturer profile

Official Manufacturer Sources

Original maker catalogue evidence used for the model values above. Review the latest datasheet, ordering chart and approval scope for the specific suffix.

LEFOO original LF16 technical product reference

LF16 — water pump pressure hysteresis

LF16 is a mechanical pressure-control switch for a water pump. Select a cut-in pressure that maintains required delivery pressure and a cutout below system maximum pressure, accounting for pressure-tank precharge. Test the actual differential and pump restart frequency with a gauge. Contact current, waterproofing of electrical entries and medium-facing materials must match the installation; the switch is not a dry-run protection system unless separately documented.