Products & Manufacturers / Controls & HVAC Equipment / Pressure Switches / LEFOO LF18 Three-Phase Compressor and Water Pump Pressure Switch
LEFOO ยท THREE-PHASE PUMP/COMPRESSOR SWITCHING

LEFOO LF18 Three-Phase Compressor and Water Pump Pressure Switch

LEFOO LF18 original product photo
LEFOO LF18 ยท Manufacturer image and specification

Three-phase pump/compressor switching in the LEFOO LF18 family. The correct operating range, contact wiring and hydraulic or pneumatic installation depend on the ordered variant.

LF18Air or water, confirm wetted variantMechanical / control engineering

Model Identification & Key Specifications

ManufacturerLEFOO
ModelLF18
Product roleThree-phase pump/compressor switching
Working mediumAir or water, confirm wetted variant
Maker-listed setting envelopeBands 1โ€“5, 2โ€“8, 3โ€“11, 4โ€“16 bar
Electrical switching400 VAC options rated 16 A or 25 A, configuration-specific
Options / family variantsMechanical pressure reset differential and optional unloader
Manufacturer technical sourceOriginal model source linked below
OEM specification scope: Published family data must be checked against the exact motor, process medium, selected factory pressure points and delivered model suffix. A structural maximum pressure is never automatically the allowable switching setpoint.

Manufacturer Technical Data

Three-phase NC compressor switch has four listed operating bands 1โ€“5, 2โ€“8, 3โ€“11 and 4โ€“16 bar with matching differentials 1โ€“3, 1โ€“3, 1.4โ€“4 and 1.8โ€“4.5bar. Listed 400VAC three-phase 16A/25A must be verified against the ordered contact configuration; optional unloader avoids restarting an air compressor against residual head pressure. Mechanical high/low cut-in thresholds are not analog sensing outputs.

AirAlign Engineering & Selection Analysis

Four operating bands have different cut-in/cut-out differentials: choosing the widest pressure span does not prove the same contact ratings or accessories. Unloader tubing applies to compressor duty and cannot be assumed necessary for every water-pump assembly.

Correct system operation is determined by the restart threshold, stop threshold, motor electrical duty and the available pressure supply. An adjustment range does not imply every combination is approved: compare manufacturer-specified differential, pressure proof, operating medium and fitting. For motor-driven equipment, locked-rotor conditions, overload protection and cycling frequency are separately important even where a contact-current rating is published.

Installation, Compatibility & Protection

Pressure settings

Specify both cut-in and cut-out conditions for the intended equipment, and verify the manufacturer’s permitted hysteresis. Do not use proof or burst pressures as running thresholds.

Contact configuration

NO and NC contacts have different protection and restart behavior. Match the wiring schedule and motor/contactor duty, rather than relying only on voltage and ampere numbers.

Medium and threaded port

Verify actual air versus water compatibility, wetted materials, connection thread standard, sealing method and temperature of the process. The manufacturer variant must support the full application.

Component approval

Manufacturer certificates and conformity documents should be interpreted only for the models and revisions explicitly covered.

LF18 Three-Phase Ordering Range Comparison

LF18 combines three-phase motor switching with an adjustable tank-pressure operating function. The OEM parameter table lists Air as the medium; despite the broader compressor/water-pump product-family name, determine wetted-material and water-system suitability for a particular LF18 order code before use with water.

Available operating classPublished factory cut-in / cut-outListed differential
1โ€“5 bar2 / 4 bar1โ€“3 bar
2โ€“8 bar3.8 / 5.0 bar1โ€“3 bar
3โ€“11 bar5.6 / 7.0 bar1.4โ€“4.0 bar
4โ€“16 bar8.0 / 10.0 bar1.8โ€“4.5 bar
Motor/load selection: LEFOO lists 16 A and 25 A at three-phase 400 VAC depending on configuration. These are not interchangeable motor-start ratings. Verify all three poles, motor protection, the relief system, pressure-port size and whether the selected model has an unloader valve or manual isolation knob.

Evidence: LEFOO LF18 option tables and documentation. Compare LF12 for different thermal-relay and wiring choices.

Related Models & AirAlign Categories

LEFOO LF12 Three-Phase Compressor Switch ยท LEFOO LF19 Compressor / Pump Switch ยท Pressure Switches ยท LEFOO manufacturer profile

Official Manufacturer Sources

Original maker catalogue evidence used for the model values above. Review the latest datasheet, ordering chart and approval scope for the specific suffix.

LEFOO original LF18 technical product reference

LF18 โ€” three-phase pump and compressor differences

LF18 is listed for three-phase compressor/water-pump duty, but those services have different media and motor restart behavior. Select the actual wetted diaphragm, tank piping and pressure range for air or water, and coordinate contacts with the proper rated motor starter/overload. Compressor unloading may be required for air service but not equivalent for a water pump. A three-phase switching label is not a guarantee that all motor currents can pass through the pressure control directly.