Products & Manufacturers / Controls & HVAC Equipment / Pressure Switches / LEFOO LF12 Three-Phase Air Compressor Pressure Switch
LEFOO · THREE-PHASE COMPRESSOR PRESSURE CONTROL

LEFOO LF12 Three-Phase Air Compressor Pressure Switch

LEFOO LF12 original product photo
LEFOO LF12 · Manufacturer image and specification

Three-phase compressor pressure control in the LEFOO LF12 family. The correct operating range, contact wiring and hydraulic or pneumatic installation depend on the ordered variant.

LF12Compressed airMechanical / control engineering

Model Identification & Key Specifications

ManufacturerLEFOO
ModelLF12
Product roleThree-phase compressor pressure control
Working mediumCompressed air
Maker-listed setting envelopeFactory pressure settings: verify exact ordering variant
Electrical switching400 VAC 7.5/11 A; 690 VAC 4.5/6.5 A option-dependent
Options / family variantsThermal relay and compressor unloader options
Manufacturer technical sourceOriginal model source linked below
OEM specification scope: Published family data must be checked against the exact motor, process medium, selected factory pressure points and delivered model suffix. A structural maximum pressure is never automatically the allowable switching setpoint.

Manufacturer Technical Data

Three-phase multipole NC switch offers motor thermal relay options and an unloaded compressor start valve. OEM table varies ratings dramatically: 400VAC 7.5A/11A and 690VAC 4.5A/6.5A options rather than one universal three-phase rating. Manufacturer says thermal overload relay may require 30-minute cooldown and motor cycling interval above five minutes. The cited CE document concerns the 2014/35/EU low-voltage requirements for its stated scope.

AirAlign Engineering & Selection Analysis

The thermal relay protects against overheating only as specified for the chosen motor configuration. A manual reset or cooling delay can change restart behaviour, so the switch must not be treated as a generic three-pole mains isolator.

Correct system operation is determined by the restart threshold, stop threshold, motor electrical duty and the available pressure supply. An adjustment range does not imply every combination is approved: compare manufacturer-specified differential, pressure proof, operating medium and fitting. For motor-driven equipment, locked-rotor conditions, overload protection and cycling frequency are separately important even where a contact-current rating is published.

Installation, Compatibility & Protection

Pressure settings

Specify both cut-in and cut-out conditions for the intended equipment, and verify the manufacturer’s permitted hysteresis. Do not use proof or burst pressures as running thresholds.

Contact configuration

NO and NC contacts have different protection and restart behavior. Match the wiring schedule and motor/contactor duty, rather than relying only on voltage and ampere numbers.

Medium and threaded port

Verify actual air versus water compatibility, wetted materials, connection thread standard, sealing method and temperature of the process. The manufacturer variant must support the full application.

Component approval

Manufacturer certificates and conformity documents should be interpreted only for the models and revisions explicitly covered.

LF12 Three-Phase Motor Selection: Practical Checks

LF12 is not just an air-pressure switch with an extra terminal. LEFOO specifies multiple contact ratings for different motor supply configurations. A three-phase nameplate alone does not establish the electrical load that the delivered switch can safely interrupt.

Supply / applicationManufacturer-listed alternativesWhat to check
Single phase120 or 230 VAC: 10 ACheck installed motor and starting method.
Three phase, 400 VAC7.5 A or 11 A optionsConfirm the exact version, not the higher of two ratings by default.
Three phase, 500 VAC6 A or 9 A optionsVerify contact/motor combination and wiring diagram.
Three phase, 690 VAC4.5 A or 6.5 A optionsDo not extrapolate a 400 VAC value to 690 VAC.
Thermal overload relayOptional accessory/variantMatch motor setting, fault response and maker reset/cooldown instructions.
Electrical integration: LEFOO notes more than five minutes between motor cycles and a thermal relay cooling period around 30 minutes. Confirm that the operating sequence meets the actual motor and device documentation; overload protection and pressure control serve separate functions.

Evidence: LEFOO LF12 rated contact and motor-control options. Factory setpoints, connector arrangement, thermal relay setting and model certification must be resolved by order suffix.

Related Models & AirAlign Categories

LEFOO LF15 Air Compressor Switch · LEFOO LF18 Three-Phase Pressure Switch · Pressure Switches · LEFOO manufacturer profile

Official Manufacturer Sources

Original maker catalogue evidence used for the model values above. Review the latest datasheet, ordering chart and approval scope for the specific suffix.

LEFOO original LF12 technical product reference

LF12 — three-phase motor switching coordination

LF12 is a three-phase compressor pressure switch family; motor circuit coordination must match contact ratings, phase voltage, overload protection and starter contactors. A pressure limit does not replace motor thermal overload or short-circuit protection. Determine the switch’s actual cut-in/cutout differential and air-unloader arrangement if present, rather than assuming all LF12 codes include the same mechanism. Qualified wiring is essential before connecting a three-phase motor.