LEFOO · LIQUID FLOWMETERS

LEFOO LFUD106 Ultrasonic Open-Channel Flow Meter

Original maker LEFOO LFUD106 Ultrasonic Open-Channel Flow Meter. This named model has different physical design/ultrasonic application from sibling LFUD models and must not be conflated across product suffixes.

Manufacturer technical and installation distinctions

PrincipleNon-contact ultrasonic head above open-channel weir/flume, flow computed by channel geometry
Flow range0–100,000 L/s manufacturer 2025 sensor catalog
Blind zone0.25–0.8m
Accuracy/resolution±0.5% manufacturer catalog reference; 1mm level resolution; project-specific flume calibration required
Output4–20mA and RS485
IngressConverter IP65, ultrasonic probe IP68 — these are not interchangeable
ATEX/IECExCurrent issued Ex approval not established

Original LEFOO Sensor Products catalog, ultrasonic table and photos (page 29 in printed booklet) · LEFOO source model directory

Verified manufacturer model existence, distinct specs and original photo location on 23 October 2026. Exact cropped original photo / certificate and all part-number combinations remain open.

LFUD106 — open-channel flow needs weir/flume calibration

LFUD106 does not directly detect flow velocity inside a pipe. It measures ultrasonic water level above an open-channel weir or flume and computes discharge using the configured hydraulic geometry and flow equation. The maker’s broad listed flow envelope therefore cannot be applied without a correctly installed channel and known head-to-flow relationship. Keep the sensor outside its near-field dead zone; distinguish the IP68 probe from IP65 control housing and verify 4–20 mA/RS485 scaling.