STS SLS01 Sewage Lift Station Level Measurement Kit

Model-specific technical specifications
Manufacturer sewage lift station measurement kit for clog-resistant level monitoring. STS lists measurement 2.5–150 psig, accuracy ±0.25% FS, current output and stainless-steel/titanium wetted hardware. Kit contents, electrical accessories and mounted probe depend on ordering configuration.
Manufacturer documentation
Original STS SLS01 product page and datasheet.
Engineering note: Confirm real order-code components, site installation, cable/accessory ratings and local safety requirements. FM/FM-C approval and CE conformity, where listed by STS, do not automatically establish ATEX/IECEx or certified Ex installation.
SLS01 lift-station kit commissioning
A sewage lift-station level kit is a packaged measurement solution, not only a probe. Confirm what components are included in the ordered SLS01 kit—submersible sensor, mounting accessories, cable, surge protection and any signal-conditioning hardware—before using a catalog photo as a bill of materials. For wastewater applications, plan for ragging, sludge, turbulence and ease of retrieval/cleaning, as well as density and barometric effects on pressure-derived level. The site’s nominal 2.5–150 psig and ±0.25% FS values are family information; verify the configured span and 4–20 mA scaling with the lift-station controller. Neither FM-C nor generic CE evidence should be represented as universal Ex approval.