LEFOO LFM208 Residual Pressure Transducer
Residual pressure measurement sensor/transducer in the LEFOO LFM portfolio. This exact model identifier appears in LEFOO’s official download list.
Manufacturer: LEFOO
Manufacturer Technical Data
LEFOO official downloadable datasheet index (find LFM208) →
Consult exact datasheet for range, accuracy, power supply, environmental limits and options. This entry identifies a catalog model, not every option/SKU.
Model-specific datasheet and ordering detail — verified 23 October 2026
LFM208 is a MEMS low-pressure residual/differential air-pressure and smoke-control transducer used for stairwell pressurisation / lift lobby monitoring. Official LEFOO technical sheet specifies a nominal ±100 Pa family measurement range, ±1% FS accuracy at 25°C, 1000 Pa withstand, 24 VDC ±10% supply, IP30, and operation from −10 to +60°C in that original PDF revision. Manufacturer document discrepancy: LEFOO’s current live LFM208 product page lists an operating range of −20 to +75°C (and compensation −5 to +60°C), while the maker-hosted PDF lists −10 to +60°C operation/compensation. The two figures are not reconciled; check the ordered hardware revision and current factory datasheet before specifying ambient limits. Sensor measures air / non-aggressive gas, not fluid process pressure. The product has separate status and alarm LEDs and may be ordered with or without display.
Supplier ordering-guide options: 2530 denotes the 20–30 Pa residual pressure selection, 4050 denotes 40–50 Pa; screen N absent or D present; communications R = RS485 or P = Pb two-bus. The manual contains a partial selection example. These options are set-point / application selections and do not imply every cross-combination is currently sold.
Certificate scope: TÜV SÜD attestation E8A 108521 0004 Rev. 00 names the LFM208 among LFM108/LFM11/LFM3/LFM5 for EU EMC Directive 2014/30/EU, EN 61326-1:2013 (dated 9 April 2021). The attestation applies only to the stated electromagnetic-compatibility requirements and named models.
Original LEFOO LFM208 model photo, ranges and ordering guide (PDF) · Original TÜV SÜD EMC attestation covering LFM208 (not Ex).
LFM208 residual pressure
‘Residual pressure’ requires a definition of the measured reference, process media and operating span before sensor selection. Determine whether the LFM208 is intended for gauge, vacuum or specialized system monitoring, and obtain its original technical drawing. Check port materials, transient load, output scale and host integration. Its LFM family membership does not justify borrowing the 4–20 mA or pressure limits of an unrelated differential model.