Produal RT-CO2 Room Carbon Dioxide Transmitter
Room carbon dioxide transmitter in Produal’s RT room solutions.
Manufacturer: Produal
Verified Product Information
| Measurement | CO₂ |
|---|---|
| Product family | RT |
| Application | Indoor CO₂ monitoring |
Official Manufacturer Source
Open manufacturer model / catalog information →
Electrical specifications, current availability, measurement claims and hazardous-area approvals depend on the actual configuration and revision. Verify the original manufacturer documentation before specifying equipment.
Produal RT-CO2 — simple room NDIR CO₂ with selectable network — engineering specifications
Original maker documentation distinguishes the ordered hardware’s measured channels, outputs and qualified use cases. Optional feature lists do not establish that every product variant contains every sensor, controller or protocol.
| Feature | OEM information | Engineering limits |
|---|---|---|
| Measured signals | Room CO₂ concentration and ambient temperature; RH on optional variant | No guaranteed humidity measurement on a CO₂/temperature-only order code. |
| Concentration class | Room CO₂ for ventilation control and occupant trends | Use reference-calibrated sensing for high-stakes life-safety applications. |
| Analog versus bus | Individually configurable measured outputs; optional Modbus RTU or BACnet MS/TP | The network order code, addresses and controller object map matter. |
| Commissioning | MyProdual smartphone software plus upgraded MyTool Connect Bluetooth dongle | App alone does not substitute for hardware adapter. |
| Physical installation | Wall or flush mounting box for dry room environment | Cold outside walls and occupant direct breathing plume distort readings. |
| Application scope | Simple building automation instead of multifunction RTX touchscreen/PI controller | Do not transfer RTX-D control functions to RT-CO2. |
| Environmental / performance | Separate order codes/suffixes determine temperature/RH spec and analog scaling | Use current order-code datasheet for numeric accuracy, not copied family claims. |
Commissioning and application guidance
For a VAV demand-controlled ventilation loop, log actual CO₂ ppm, verify selected output span and any room temperature points, then map alarm thresholds to a documented ventilation strategy. Humidity and BACnet are not mandatory on every RT-CO2; compare RT and RTX series before upgrading from an analog-only control system. If using automated baseline calibration, ensure the monitored room reaches a representative outdoor background periodically. The manufacturer’s RT transmitter is intended for measurement/ordinary BAS and is not a worker-entry gas alarm.
Original manufacturer: Official model information, technical documents and configurator. Confirm final ordered SKU, supplied options and current data before control or safety-critical use.
AirAlign independent model-specific technical review · 25 October 2026. OEM technical claims are not third-party calibration or Ex/SIL approval.