CAMPINI COREL · PRESSURE SENSORS

Campini Corel TY 87H Pressure Transducer

Campini Corel TY 87H official manufacturer model photo
Official Campini Corel product photo; displayed examples may include multiple variants of the named model.

Industrial/HVAC pressure transducer family; original manufacturer lists TY 87H among pressure controls.

Original manufacturer: Campini Corel, Italy.

Certification: Pressure switch/thermostat compliance is not equivalent to Ex/ATEX hazardous-area approval. No Ex claim has been made here.

Original Manufacturer Catalog

Official Campini product family / model →

TY 87H is listed by the manufacturer as a pressure transducer, not a mechanical switching pressurestat. Confirm the electrical transfer function, connector, calibrated range and installation approval against the ordered device documentation.

TY 87H — manufacturer-confirmed pressure and environmental specifications

Campini Corel lists TY 87H as a pressure transducer intended for wall-mounted boilers and pellet stoves. It should not be presented as a simple snap-action pressure switch without evidence of an actual relay contact.

Original maker parameterPublished TY 87H valueEngineering interpretation
Orderable pressure span choices0–3 / 0–4 / 0–5 / 0–5.5 barChoose full scale by exact ordered suffix, not a generic 5.5-bar assumption.
Rupture pressure>30 barDestructive rupture limit is not allowed continuous working pressure or an independent pressure safety rating.
Current consumption<10 mASource does not give a universal operating supply or output type; obtain the exact variant drawing / test documentation.
Ingress protectionIP00Do not install as a weatherproof or washdown-rated field sensor without a separately engineered protective enclosure.
Working temperature−15…+90°CConfirm pressure-medium compatibility, mounting thermal gradients and long-term stability for boiler hydraulics.
Electromagnetic standardsEN 55032 and EN 61000-4-2/-3/-4/-6/-8 listedThese relate to EMC design; they do not prove ATEX/IECEx or pressure-equipment certification.

Integration and replacement checklist

Document media, gasket/seal, pressure port size, calibrated full-scale variant and host signal mapping. Verify whether the original unit is used for continuous measurement or a controller-derived cutout; do not conflate transducer pressure measurement with an independently rated overpressure relief or limit switch. The manufacturer’s public page does not provide a model-independent analogue transfer curve; that parameter remains pending OEM documentation.

Original model reference: Campini Corel TY 87H current product specifications.