WINSEN · PHOSPHINE (PH₃) SENSORS

Winsen ZE03-PH₃ Phosphine Module

Winsen ZE03 sensor family illustration — exact gas-specific variant may differ
Illustrative manufacturer family image; exact configuration may vary.

PH₃-calibrated ZE03 electrochemical module for specialist toxic-gas sensing.

Manufacturer: Winsen

Technical details

Target gasPH₃
Gas-specific range in manufacturer manual0–1,000 ppm
InterfaceUART and analog voltage
Technical noteCheck exact ordered cell and calibration

Official technical source

Manufacturer model information →

For engineering use, confirm the exact variant, manufacturer datasheet and instrument-level compliance.

ZE03-PH₃ — specialist toxic-gas integration

ZE03-PH₃ is positioned for phosphine detection, with a manufacturer-family listing reaching up to 1,000 ppm in some configurations. That broad span should not be taken as an appropriate life-safety alarm threshold or accuracy claim for every ordered cell. The actual model’s calibration, response time, interfering gases, humidity tolerance and signal scaling must be documented. The generic ZE03-family illustration does not establish approved personal monitoring or ATEX/IECEx system certification.

ZE03-PH₃ — phosphine-sensitive electrochemical module — gas-specific selection

The Winsen ZE03 electronics are a shared platform, but the Phosphine (PH₃) electrochemical cell, calibrated units, interfering gases and analog voltage direction are model-specific.

SpecificationManufacturer evidenceIntegration concern
Gas-specific cartridgePH₃ electrochemical cartridge integrated into common ZE03 electronicsPH₃ is highly toxic; do not reuse SO₂ or ozone calibration.
Range and sensitivityWinsen family page lists PH₃ but defers measurement range to variant/manualDo not invent 0–20 ppm or an alarm threshold in the absence of ordered part datasheet.
Digital and analog3 V TTL UART plus analogue amplified voltage provided by ZE03Check serial decimal/signed data and analog polarity for PH₃-specific element.
Electrical supply5.0 ±0.1 V DC, under 5 mA for general ZE03 boardUse 5 V sensor rail and a host-safe logic-level connection.
Ambient and mechanical−20 to +50 °C, 15–90%RH noncondensing, Ø23.5 ×24.5 mmGrain silo/fumigation environments require ingress and humidity protection.
Service planningGeneral module two-year nominal expected lifeConfirm PH₃ cell poisoning/cross sensitivity and exact calibration interval.

Commissioning, cross sensitivity and safety

PH₃ may be used in fumigation, where a delayed or incorrect sensor reading can be a serious safety issue. The original Winsen listing does not expose the PH₃ cell’s exact range, cross-gas factors or alarm performance; this must be provided by the OEM before design acceptance. Use a chemically suitable remote sampling path or controlled installation position, maintain dedicated reference gas testing and never represent a general-purpose OEM module as a self-contained personal safety detector or site Ex-certified gas alarm.

OEM source: Winsen ZE03 family and gas-specific manufacturer documentation. Calibrated gas, output map and regional certificate require precise ordered part documentation.

AirAlign model-specific technical editorial update · 25 October 2026; not a certified finished gas-safety device.