SENKO · HYDROGEN SULFIDE (H₂S) SENSORS

SENKO SS4198 H₂S Electrochemical Sensor

SENKO SS4198 electrochemical H2S sensor

Electrochemical hydrogen sulfide sensor for fixed or portable industrial instruments.

Manufacturer: SENKO

Technical specifications

Target gasH₂S
Measurement range0–200 ppm
Maximum overload1,000 ppm
T90 responseUnder 35 seconds
Operating temperature−20 to +50 °C

Manufacturer documentation

Official product information / technical documents →

Verify exact gas configuration, part number, calibration, response, environmental limits and applicable safety certification before equipment design-in. Product data can change between revisions. AirAlign is independent of the listed manufacturer.

SS4198 H₂S — sensing span versus overload and maintenance

SENKO identifies SS4198 as a 0–200 ppm H₂S electrochemical cell with 1,000 ppm maximum overload, a manufacturer sensitivity of 380 ± 80 nA/ppm and T90 below 35 seconds. The overload figure is a survivability limit, not an extended calibrated 1,000 ppm reporting range. Transimpedance electronics, temperature correction and field calibration determine usable instrument performance.

The manufacturer positions the cell for portable and fixed detection in wastewater, mining and industrial safety. For alarm integration, allow for diffusion delay, inlet filters, humidity, H₂S sensor poisoning/consumption and the cell’s finite service life (manufacturer cites more than 24 months under stated conditions). Compare current sensor data and assembled-instrument certifications before assigning any alarm or intrinsically safe rating.

Original manufacturer: Product specifications and documentation. Check current model suffix, revision and safety documentation before design-in.