ELICHENS · COMBUSTIBLE GAS SENSORS

eLichens Mulberry Duo CH₄ CO₂

Official eLichens mulberry-duo sensor family product image
Official manufacturer family image; selected gas version may differ.

Manufacturer: eLichens

Dual-gas NDIR module. Please check the gas-specific variant and current documentation before selection.

Technical specifications

Target gases CH₄ and CO₂
Technology Dual-channel NDIR
Output Digital interface; confirm datasheet
Form factor Mulberry sensor family

Official manufacturer documents

Product family, documentation and datasheets ↗

Reviewed: 17 October 2026. Data is specific to the product family unless an exact variant is stated; no unsupported measurements are inferred.

Mulberry Duo — two gases from one assembly

The Mulberry Duo is described as a methane and carbon-dioxide NDIR measurement module. A host must identify the two separate gas values, their calibration and units, and the required digital frame format before using the data for equipment control. Methane safety alarms and CO₂ concentration monitoring serve different hazard/control decisions; do not share one threshold or treat simultaneous dual-gas operation as identical to combining two stand-alone modules. Confirm exact spectral channels and suffix with the maker.

Mulberry Duo — simultaneous CH₄ and CO₂ in one NDIR unit: original-maker engineering review

The current eLichens gas-sensor product range distinguishes 1-Series versus 4-Series hardware, gas-specific calibration and certificate scope. Family descriptions do not establish every exact ordered module’s performance or complete-device approval.

Feature Manufacturer basis Engineering distinction
Gas channels Dedicated CH₄ and CO₂ NDIR measurements in one 4-Series assembly Not a single methane channel with a derived ‘equivalent CO₂’ output.
Electrical connection Digital UART with integrated temperature compensation Host application must parse both independent concentration channels and faults.
Power Manufacturer states <2 mW for Mulberry Duo This is model-specific; not the same as the Bilberry 5S 75 µW claim.
Deployment formats Portable or fixed gas detection instruments Integration requires mechanical diffusion opening and channel-specific alarm logic.
Protection classification Maker declares intrinsically safe ATEX and IECEx Zone 0 for Mulberry Duo Complete instrument’s energy limits, circuit parameters and nameplate still need validation.
Sensor basis Low-power micro-source and proprietary multi-channel NDIR Separate gas response/detection limits must come from order-specific Duo datasheet.
Market introduction Official launch 16 July 2026 for first eLichens dual-gas Mulberry Do not merge this new 2026 hardware with older standalone Mulberry CO₂ or CH₄ modules.

Integration and safety assessment

The dual-channel approach may help distinguish environmental CO₂ backgrounds from methane gas leaks in biogas or utilities, but each channel needs independent calibration gases, units and alarm settings. CO₂ ppm/percent volume is not a proxy for combustible %LEL and does not alone prove a methane release. For hazardous area designs, inspect the Duo-specific entity parameters and approved enclosure/host before claiming that a complete device is Zone 0 approved. Test channel faults separately and avoid propagating one sensor’s stale gas value as a healthy value for both.

Original maker: eLichens current NDIR gas-sensor product specifications and downloadable variant datasheets. Verify the exact model’s sensor code, current Ex certificate and installed OEM integration requirements before selection.

AirAlign technical editorial note · 25 October 2026; detailed prototype/selection reference, not independent certification or calibration.