INFINEON TECHNOLOGIES · PHOTOACOUSTIC CO₂ SENSOR

Infineon Technologies PASCO2V15

Legacy XENSIV™ PAS CO₂ 5 V photoacoustic spectroscopy sensor.

Photoacoustic CO₂DiscontinuedOptical / acoustic sensing
Product lifecycle: Discontinued. This is a legacy / discontinued reference, not a recommendation for new product design.

Key Specifications

MEASUREMENT TECHNOLOGYPhotoacoustic infrared CO₂ sensing
SPECIFIED CO₂ RANGE400–3,000 ppm (accuracy specified)
CO₂ ACCURACY±(50 ppm + 5% of reading)
RESPONSE TIME55 s
SUPPLY VOLTAGE3.3–5 V
OUTPUT / INTERFACEI²C, UART, PWM
PRODUCT STATUSDiscontinued
SOURCE VERIFIED13 October 2026
AirAlign technical note: Infineon explicitly marks PASCO2V15 discontinued / end of life. The manufacturer also lists a wider 0–32,000 ppm reporting range; this is not the same as its accuracy-specified range. Legacy reference only.

How Photoacoustic CO₂ Sensing Works

The sensor modulates infrared light near a CO₂ absorption wavelength. When the gas absorbs the light, periodic heating creates a small pressure or acoustic signal. An acoustic detector measures the signal and the device’s electronics estimate carbon dioxide concentration, applying compensation and calibration as specified by the manufacturer.

Integration Considerations

Verify measurement conditions, automatic baseline correction requirements, installation environment, power peaks, bus communications, humidity and pressure effects, and manufacturer lifecycle status before product selection. Accuracy ranges should not be confused with digital reporting or output ranges.

Official Manufacturer Source

Product information and lifecycle status should be checked against the current manufacturer listing.

View PASCO2V15 official product page →

AirAlign is an independent technical information resource and is not affiliated with Infineon Technologies. Specifications and product availability can change.

Infineon PASCO2V15 — discontinued 5 V-emitter PAS CO₂ — model-specific datasheet review

These original manufacturer specifications are bounded to their stated measurement conditions. Output coding, calibrated precision, voltage domains, firmware and lifecycle status are not universal across variants.

PropertyOfficial model specificationEngineering limitation
Product lifecycleOfficial Infineon status discontinued / end of life for PASCO2V15AUMA1Not suitable for fresh system design without an active replacement selection.
CO₂ technologyPhotoacoustic spectroscopy with MEMS microphoneDirect CO₂ ppm readout, not estimated eCO₂ from VOC.
Specified accuracy band400–3,000 ppm, ±(50 ppm + 5% of reading)Worse rated accuracy than PASCO2V01’s historical 400–5,000 ppm band.
Output envelope0–32,000 ppm digital readoutDo not call this the manufacturer’s full calibrated accuracy interval.
Nominal supply design5 V emitter with separate digital-side supply management; official family listing 3.3–5 VNever wire PASCO2V15 to the V01’s 12 V emitter connection.
InterfacesI²C, UART, PWMFirmware readout and timing must match actual variant.
Response~55 s per manufacturer catalogFaster nominal response than legacy PASCO2V01 (90 s), still enclosure-dependent.
Operating environment / package0…+50 °C; 13.8 × 14 × 7.5 mmMechanical similarities cannot prove pin-compatibility.
Vendor orderingPASCO2V15AUMA1 now discontinuedRepair availability does not equal active OEM production.

Selection, calibration and application

Infineon’s original source calls PASCO2V15 the 5 V version; it is a historical product and currently discontinued. The 400–3,000 ppm accuracy band and 55 s reference response differ from PASCO2V01 despite common PAS family naming. Do not transfer the 12 V emitter design, ±(30 ppm +3%) figure or response value from PASCO2V01. Selection for new HVAC or IoT designs requires a currently supported Infineon alternative and complete electrical/firmware migration check. Retain pressure compensation, clean-air baseline offset calibration assumptions and appropriate air exposure when maintaining installed boards.

Original manufacturer references: Infineon PASCO2V15 — discontinued 5 V-emitter PAS CO₂ official product data. Latest order code, precise calibrated concentration band and regulatory requirements must be checked before deploying a sensing or safety solution.

AirAlign technical editorial review, 25 October 2026. Not a substitute for current device-specific measurement calibration or certificates.