Telaire T6713

A miniature NDIR CO₂ module designed for OEM indoor air quality and demand-controlled ventilation applications, with Telaire ABC Logic self-calibration.

NDIRCO₂I²CUART / ModbusPWM

Key Specifications

MODELT6713 Series
MEASUREMENT TECHNOLOGYNDIR · gold-plated optics · diffusion sampling
MEASUREMENT RANGE0–5,000 ppm
ACCURACY±30 ppm + 3% of reading (400–5,000 ppm)
RESPONSE TIME<3 min T90 typical
WARM-UP<2 min operational · 10 min max accuracy
POWER SUPPLY4.5–5.5 V DC
CURRENT200 mA peak · 25 mA average
INTERFACESI²C · UART with Modbus support · PWM
SIGNAL UPDATEEvery 5 s
OPERATING TEMPERATURE−10–60 °C
OPERATING HUMIDITY0–95% RH, non-condensing
DIMENSIONS30 × 15.6 × 8.6 mm
STABILITY<2% FS over sensor life (15 years typical)
Accuracy note: Manufacturer accuracy depends on stated SATP/span-gas conditions. Telaire also notes a possible additional tolerance when first installed that is corrected by ABC Logic over the first weeks.

Product Positioning

Telaire describes the T6713 as an affordable OEM sensing platform for HVAC transmitters, air-to-air heat exchangers, air conditioners and handheld meters.

Official Resources

Technical data on this AirAlign page is based only on the manufacturer’s official product information. For integration, compliance and purchasing decisions, verify the latest manufacturer documentation.

View Telaire T6713 Official Page

AirAlign is an independent informational resource and is not affiliated with the manufacturer. Specifications can change; manufacturer documentation remains authoritative.

Amphenol Telaire T6713 — calibrated 5,000 ppm OEM NDIR: OEM specifications and integration

The manufacturer publishes model- and range-specific measurement data; numerical test values, measurement accuracy and digital output envelope are not interchangeable.

SpecificationOfficial product dataEngineering consequence
Optical technologyGold-plated non-dispersive infrared optics; diffusion samplingNot photoacoustic, despite similar digital ppm readout.
Concentration range0–5,000 ppm digital output; accuracy at 400–5,000 ppm ±(30 ppm + 3% reading)Technical upper display range is distinct from calibrated range.
Response and refresh90% response in <3 min typical; data every 5 sFrequent polling cannot overcome slower diffusion response.
StartupBelow 2 min operational; approximately 10 min to maximum accuracyAvoid setting commissioning alarm thresholds during initial stabilization.
Temperature and moisture−10…+60 °C; 0–95%RH noncondensingAvoid air-conditioner discharge, condensation and sensor face obstruction.
Long-term calibrationABC Logic self-calibration; <2%FS drift cited over typical 15-year lifetimeABC algorithms expect periodic low-CO₂ exposure, not constantly enriched air.
Mechanical / supply30 × 15.6 × 8.6 mm; nominal regulated 5 V supplyHold voltage and ground within OEM noise guidance.

Application, calibration and design details

Telaire’s ABC Logic self-calibration expects an appropriate background minimum, with manufacturer notes that exposure below 400 ppm for more than 15 minutes can affect the algorithm. High-occupancy commercial, mushroom and greenhouse settings may not deliver the necessary calibration baseline; plan checks against certified reference gas instead of calling the sensor forever calibration-free. Do not mix T6713’s accuracy ±(30 ppm+3%) with the cheaper T6703’s ±75 ppm or 10% of reading. The original T6713 module may have additional sensor suffixes and header connection choices.

Model-specific manufacturer source: Original technical specifications and supporting product documentation. Refer to current datasheet revision and supplied hardware code when procuring and certifying an instrument.

AirAlign editorial enhancement · 25 October 2026. Manufacturer-declared performance is not independent metrological or Ex-area certification.