Manufacturer-verified NDIR CO₂ sensor module for OEM integration. Specifications below use the manufacturer’s published information for the displayed model.
Key Specifications
Product Positioning
Telaire T6703 is part of TELAIRE / AMPHENOL’s NDIR CO₂ module portfolio for integration into air-quality, HVAC, building or industrial equipment.
Official Resources
Use the manufacturer’s current documentation as the authoritative source for integration and purchasing.
View TELAIRE / AMPHENOL Official ResourceAirAlign is an independent informational resource and is not affiliated with TELAIRE / AMPHENOL. Specifications can change.
Telaire T6703 — consumer-grade CO₂ module, distinct from T6713: OEM specifications and integration
The manufacturer publishes model- and range-specific measurement data; numerical test values, measurement accuracy and digital output envelope are not interchangeable.
| Specification | Official product data | Engineering consequence |
|---|---|---|
| Sensor principle | Gold-plated optics NDIR CO₂ with ABC Logic | Miniature optical gas sensor, not SGP-style VOC equivalent CO₂. |
| Measurement range | 0–5,000 ppm family | Do not assume all analog module versions use identical calibrated full-scale. |
| Accuracy at 400–5,000 ppm | ±75 ppm OR 10% of reading, whichever is greater | Accuracy grade is significantly looser than T6713 ±(30 ppm +3%). |
| Data / response | New reading every 5 s; T90 below 3 min | Digital sampling interval is not response-time guarantee. |
| Initial readiness | Operational in <2 min; highest accuracy after about 10 min | Startup state should be visible to BAS host during initial powering. |
| Environmental | −10…+60 °C, 0–95% RH noncondensing | Humidity condensation disrupts diffusion and optics. |
| Lifetime / stability | Maker cites typical 15-year sensor life, <2%FS lifetime stability | This is a product design statement conditional on service and calibration environment. |
| Supply and footprint | Nominal regulated 5 V; 30 × 15.6 × 8.6 mm | Keep OEM connector and supply filtering guidance. |
Application, calibration and design details
T6703 is targeted at residential and consumer products where cost and general room ventilation matter; T6713 is a higher accuracy grade for demanding DCV. The accuracy formula uses the greater of ±75 ppm or ±10% of reading, not a sum. ABC Logic relies on recurring outdoor-like CO₂ exposure; avoid unqualified calibration-free claims in always-occupied rooms. Align the 0–5,000 ppm output, relay/controller alarm unit scaling and module communication with the right T6703 order number. Do not confuse T6703 with a T6700 parent family brochure or T6713.
Model-specific manufacturer source: Original technical specifications and supporting product documentation. Refer to current datasheet revision and supplied hardware code when procuring and certifying an instrument.
AirAlign editorial enhancement · 25 October 2026. Manufacturer-declared performance is not independent metrological or Ex-area certification.