SST SENSING · CO₂ SENSOR MODULE

SST SprintIR-6S

Manufacturer-verified NDIR CO₂ sensor module.

NDIRCO₂UART

Key Specifications

MODELSprintIR-6S
MEASUREMENT TECHNOLOGYSolid-state LED NDIR
MEASURED GASCO₂
MEASUREMENT RANGEUp to 100% CO₂
ACCURACYSee official specification
INTERFACES / OUTPUTSUART
Specification note: Consult the current manufacturer datasheet for complete electrical, environmental and variant-specific specifications.

Product Positioning

SST SprintIR-6S is part of SST SENSING’s NDIR CO₂ sensing portfolio for OEM integration.

SprintIR-6S: High-Concentration OEM Selection

Intended measurement scale: The manufacturer family is represented with configurations reaching 100% CO₂. An option described as “up to 100%” does not establish that every SprintIR-6S order code covers that span. Confirm the ordered range and quantitative accuracy from the correct technical sheet.

Interface: UART is listed. Confirm power, logic voltage, command protocol, update cadence and the handling of saturated or invalid readings. For process control, the end-to-end sampling and signal response matter more than the model name alone.

Selection distinction: SprintIR-R and ExplorIR-M also appear in AirAlign’s high-concentration NDIR catalog. Their similar upper-range descriptions must not be taken as proof of equal dynamic response, power consumption, mechanical dimensions or calibration requirements.

Sampling: Check gas-flow exposure, pressure changes, temperature and condensation before integrating this module into a chamber or inline instrument.

Official Resources

Manufacturer documentation is the authoritative source for design-in and purchasing.

View SST SENSING Official Resource

AirAlign is independent and is not affiliated with SST SENSING.

SST SprintIR-6S — 20 readings/s fast flow-through LED NDIR — original manufacturer selection data

SST’s OEM gas sensor specifications depend on the ordered range, gas flow, pressure and firmware. Reporting frequency, actual gas response and measurement uncertainty are distinct parameters.

ParameterOEM dataEngineering boundary
Measurement physicsSolid-state LED NDIR CO₂ absorption rather than chemical gas cellUnlike a generic IR room sensor, the 6S is optimized for fast flow-through test gas.
Data throughput20 CO₂ readings per secondThe 50 readings/second headline belongs to SprintIR-R, not SprintIR-6S.
Gas rangeSeparate 0–5%, 0–20%, 0–60% and 0–100% versions (depending on ordered sensor)A 100%-vol capable unit is not automatically low-ppm optimized.
Manufacturer precisionSST original SprintIR-6S product sheet states 70ppm typical grade within qualified configurationTypical precision and full-range accuracy need the exact range datasheet.
Sampling architectureSupplied flow-through adapter with high-throughput optical chamberHost gas inlet/tubing residence time and supplied flow determine actual transient.
Electrical / interfaceUART control/data; dedicated digital power rail, generally 3.3V applicationsDo not attach to a 24V PLC channel or assume native 4–20mA/RS485.
CalibrationAutomatic zeroing functions in OEM interfaceFactory or field reference gas depends on sampling gas and contamination.
Typical applicationsCO₂ suppression tests, breath/sports science, high-speed laboratory measurementsNot an intrinsic personal oxygen-deficiency alarm or independent fire safety controller.

Gas sampling, UART commissioning and error budget

A ’20 measurements per second’ sampling rate is not the same as a chamber 20Hz gas-response bandwidth. For a CO₂ fire suppression test, evaluate sample-tube adsorption, pressure, pump flow and inlet delay, and distinguish the detector’s numerical range from its gas step response. The current maker site mentions 0–100% orderable options, but model-specific sample flow, pressure and actual concentration accuracy are governed by the selected 6S range code. SST lists auto-zero and host UART control; document when calibration occurs rather than assuming factory defaults are correct for permanently elevated CO₂.

Original official specification: SST exact model page and linked latest technical documents. The actual range variant, test gas conditions and electrical datasheet must govern integration.

AirAlign editorial research — 25 October 2026. This technical reference is not independent instrument certification or full hardware acceptance.