ELT SENSOR · CO₂ SENSOR MODULE

ELT Sensor S-300

Manufacturer-verified NDIR CO₂ sensor module for OEM integration. Specifications below use the manufacturer’s published information for the displayed model.

NDIRCO₂OEM Module

Key Specifications

MODELS-300 / S-300-3V
MEASUREMENT TECHNOLOGYNDIR
MEASURED GASCO₂
MEASUREMENT RANGE0–2,000 / 5,000 / 10,000 / 20,000 / 50,000 ppm
ACCURACY±30 ppm ±3% of reading
RESPONSE TIMESee official specification
WARM-UP TIMESee official specification
DIMENSIONS33 × 33 × 13.1 mm
OPERATING TEMPERATURESee official specification
OPERATING RHSee official specification
Specification note: Variant, output and electrical options can differ. Verify the current manufacturer datasheet for the exact ordered configuration.

Product Positioning

ELT Sensor S-300 is part of ELT SENSOR’s NDIR CO₂ module portfolio for integration into air-quality, HVAC, building or industrial equipment.

Official Resources

Use the manufacturer’s current documentation as the authoritative source for integration and purchasing.

View ELT SENSOR Official Resource

AirAlign is an independent informational resource and is not affiliated with ELT SENSOR. Specifications can change.

ELT S-300 — built-in CO₂ calibration modes and factory outputs — engineering selection and model documentation

The published manufacturer values below are bounded to their orderable range, test conditions and actual interface, not general guarantees about every relative in the same sensor family.

ParameterManufacturer evidenceEngineering boundary
Sensing methodGold-plated NDIR infrared gas chamber, pre-calibrated at manufactureTrue carbon-dioxide sensing with optical stability goals, not all-gas detection.
Physical dimensions33 × 33 × 13.1 mm; about 10 g on OEM S-300 v2.82 sheetLarger than T-110 19×29.3×8.5 mm, incompatible footprint.
Range portfolio0–2k, 5k, 10k, 20k, or 50k ppm selected model versionsExact article and hardware firmware determine scaling.
Declared gradeMaker catalogue ±(30 ppm + 3% reading)Published grade depends on reference environment, offset and recalibration.
Digital outputsTTL UART, I²C, and ALARM; optional PWM/analog voltageI²C and PWM/voltage options must be wired to ordered pins/version.
Calibration functionsACDL periodic automatic calibration and MCDL non-periodic manual calibrationSelf-calibration requires adequate reference schedule; greenhouse-enriched air is a known challenge.
Installation and useGreenhouse, stock-raising, HVAC and science OEM uses per original maker sheetThese product contexts do not automatically certify it as a personnel CO₂ detector.

System integration and calibration

Use ELT Sensor S-300 current pinout, electrical rails and command codes instead of borrowing them from the S-300E/S-110 product sheets. The original versioned S-300 datasheet emphasizes both ACDL and MCDL; continuous high CO₂, grow-room production and sealed bioprocess equipment benefit from planned reference-gas manual calibration. The module provides a CO₂ sensing signal, not a complete ventilator or certified oxygen-deficiency monitor. Ensure averaging, pressure/temperature changes and sample inlet flow are represented in the controller error budget.

Source and exact-order documentation: Original manufacturer catalogue, page and/or technical data sheet. Any version- or test-bound claim must be checked against the supplied production label before procurement.

AirAlign model-specific technical editorial update · 25 October 2026. These OEM values are not independently calibrated, certified, or evidence of active supplier stock.