Ventilation Units / Energy Recovery Ventilators (ERV) / Buying Guide
Energy Recovery Ventilators (ERV): Buying and Selection Guide
This guide helps select sensible and potentially latent energy recovery systems using installed ventilation requirements and whole-life operation, rather than a single heat-recovery percentage.
First step: Determine design supply and extract airflows and calculate real external static pressure, including ducts, terminals and progressively loaded filters.
1. Determine Outdoor Air Requirements
Select the energy exchanger and understand its latent transfer capability. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
2. Compare Recovery Type and Efficiency
Compare total effectiveness separately from sensible-only efficiency. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
3. Fan Duty, Pressure and Electrical Energy
Review moisture management and high-humidity climate suitability. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
4. Moisture, Frost and Filtration
Verify cross-leakage, exhaust contamination transfer and purge controls. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
5. Installation, Noise and Access
Check fan curves, external static pressure and outdoor-air rate. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
6. Controls, Balancing and Servicing
Assess frost strategy, filters, access and control demand. Ask for certified airflow, recovery and acoustic data at comparable conditions. Regional regulations and climate design conditions can materially affect final selection.
7. Common Mistakes
Technical warning: ERV is not proof that the unit will dehumidify a building under all conditions.
- Failing to allow filter pressure increase with use.
- Assuming nominal laboratory recovery effectiveness applies to every installed airflow.
- Ignoring winter condensation, condensate line maintenance or outdoor intake placement.
- Using recirculating heating/cooling equipment as a substitute for outdoor air.
8. Pre-Order Checklist
- Design ventilation schedule, occupancy and area use.
- Outdoor air and extract balancing targets.
- Duct and equipment static pressure calculation.
- Fan energy, controls and actual recovery performance.
- Climatic frosting, moisture and bypass operation.
- Filter type and service interval.
- Noise, access, mounting and electrical supply.
- Commissioning, airflow balancing and maintenance handover.