General Life SENNA HT10S RF
SENNA HT10S RF is a General Life wireless room thermostat. The room unit communicates with a separate RF receiver, which switches compatible equipment through its relay.
Model Identification
Manufacturer: General Life
Series: SENNA
Model: HT10S RF
Category: Wireless room thermostat
Connection: Radio link to receiver; receiver relay to equipment
Room Thermostat Specifications
Receiver Specifications
Compatibility and Installation
Confirm that the heating or cooling equipment supports the receiver’s on/off relay connection, and follow the exact equipment and thermostat manuals. The RF link replaces the cable between room unit and receiver; the receiver still needs power and an equipment connection. Electrical installation should be performed by a qualified installer.
Source and Revision Notes
The technical table reports 0.3°C operating sensitivity, while general hysteresis text describes a 0.5°C default. These manufacturer statements should not be treated as equivalent specifications.
Related Pages
Wireless thermostats · SENNA series · General Life manufacturer
Official Resources
Technical data checked against the model-specific manufacturer RF product page on 11 October 2026. An explicitly matching model-family RF manual was also checked.
Official SENNA HT10S RF Product PageOfficial Model-Family RF User Manual
Official Wireless Catalog
AirAlign is an independent informational resource and is not affiliated with General Life.
Radio and switching integration — SENNA HT10S RF
The SENNA HT10S RF temperature controller’s listed size and supply are 85.7mm / 85.7mm / 33.5mm and 3V DC (2 x AAA alkaline batteries), respectively. Its separate 90mm / 90mm / 25mm receiver uses 230V (AC). Plan location, radio propagation, pairing and safe mains wiring independently.
Receiver normally-open switching is 7A (240VAC – resistive load) 10A (120VAC – resistive load) for the quoted resistive loading. Compare output type and voltage with the boiler’s input requirements; this figure is not a motor contactor or direct compressor-start rating.
The user setpoint range is (5°C) – (30°C) and operating sensitivity is 0.3°C. These fields govern control setup, not an independently verified temperature error specification. Test fail-safe reaction to battery depletion, RF loss and communication failure.
The supplied receiver/order revision determines electrical installation. Do not transfer RF figures to a wired or internet-connected sibling without the current model manual.