General Life NORA HT10S RF
NORA HT10S RF is a General Life wireless room thermostat. The room unit communicates with a separate RF receiver, which switches compatible equipment through its relay.
Model Identification
Manufacturer: General Life
Series: NORA
Model: HT10S RF
Category: Wireless room thermostat
Connection: Radio link to receiver; receiver relay to equipment
Room Thermostat Specifications
Receiver Specifications
Compatibility and Installation
Confirm that the heating or cooling equipment supports the receiver’s on/off relay connection, and follow the exact equipment and thermostat manuals. The RF link replaces the cable between room unit and receiver; the receiver still needs power and an equipment connection. Electrical installation should be performed by a qualified installer.
Source and Revision Notes
The technical table reports 0.3°C operating sensitivity, while general hysteresis text describes a 0.5°C default. These manufacturer statements should not be treated as equivalent specifications.
Related Pages
Wireless thermostats · NORA series · General Life manufacturer
Official Resources
Technical data checked against the model-specific manufacturer RF product page on 11 October 2026. An explicitly matching model-family RF manual was also checked.
Official NORA HT10S RF Product PageOfficial Model-Family RF User Manual
Official Wireless Catalog
AirAlign is an independent informational resource and is not affiliated with General Life.
NORA HT10S RF — electrical and control assessment
Room thermostat and receiver: Room unit dimensions: 85.7mm / 85.7mm / 33.5mm, supply: 3V DC (2 x AAA alkaline batteries). Receiver dimensions: 90mm / 90mm / 25mm, supply: 230V (AC). Unlike the battery room thermostat, the relay receiver’s mains connection requires qualified installation and protection.
Contact selection: Receiver NO ratings of 7A (240VAC – resistive load) 10A (120VAC – resistive load) must be compared with the actual heater/boiler thermostat input and its resistive or inductive nature. The same housing designation does not prove that a wired NORA HT10S RF sibling has an identical output.
Control and radio validation: The recorded setpoint band is (5°C) – (30°C) and operating sensitivity is 0.3°C. A sensitivity parameter does not specify installed measurement uncertainty. Verify controller heating cycles, radio pairing, battery-low indications, coverage through obstructions and behavior if link to the receiver is lost.