GENERAL LIFE · WIRELESS ROOM THERMOSTAT

General Life MITRA HT250S RF

MITRA HT250S RF is a General Life wireless room thermostat. The room unit communicates with a separate RF receiver, which switches compatible equipment through its relay.

Model Identification

Manufacturer: General Life
Series: MITRA
Model: HT250S RF
Category: Wireless room thermostat
Connection: Radio link to receiver; receiver relay to equipment

Room Thermostat Specifications

Dimensions (H/W/D)85mm / 125mm / 24mm
Power supply3V DC (2 x AAA alkaline batteries)
Temperature measurement figure (manufacturer-reported)0.1°C
Setpoint range(5°C) – (30°C)
Battery life (manufacturer-reported)1 year (2 x AAA)
Ambient operating temperature(-10°C) – (+50°C)
Storage temperature(-20°C) – (+60°C)

Receiver Specifications

Power supply230V (AC)
Dimensions (H/W/D)90mm / 90mm / 25mm
Relay NO switching current (resistive load)7A (240VAC – resistive load) 10A (120VAC – resistive load)
Ambient operating temperature(-10°C) – (+50°C)
Storage temperature(-20°C) – (+60°C)
Specification scope: These values apply to the RF configuration. The thermostat and receiver have different power supplies. The receiver’s mains supply must not be confused with the equipment’s thermostat input. Relay ratings are for resistive loads. The 0.1°C measurement figure is manufacturer-reported and does not establish an independent ±0.1°C accuracy claim.

Compatibility and Installation

Confirm that the heating or cooling equipment supports the receiver’s on/off relay connection, and follow the exact equipment and thermostat manuals. The RF link replaces the cable between room unit and receiver; the receiver still needs power and an equipment connection. Electrical installation should be performed by a qualified installer.

Related Pages

Wireless thermostats · MITRA series · General Life manufacturer

Official Resources

Technical data checked against the model’s manufacturer page and the explicitly applicable RF manual on 11 October 2026.

Official MITRA HT250S RF Product Page
Official Model-Family RF User Manual
Official Wireless Catalog

AirAlign is an independent informational resource and is not affiliated with General Life.

Wireless installation assessment — MITRA HT250S RF

Two electrical units: The MITRA HT250S RF room thermostat is 85mm / 125mm / 24mm and uses 3V DC (2 x AAA alkaline batteries), while its distinct receiver is 90mm / 90mm / 25mm and requires 230V (AC). Do not wire receiver mains into the battery-powered room unit or assume the thermostat can operate without its correct paired receiver.

Heating switching: The receiver’s published normally-open resistive load is 7A (240VAC – resistive load) 10A (120VAC – resistive load). The heat source must accept this contact topology and the selected receiver’s output wiring; a resistive rating is not an inductive pump or compressor switching certificate.

Wireless commissioning: Test radio pairing, communication reliability through the actual walls/floors, manual receiver control and safe response to a lost wireless link. The room setpoint is (5°C) – (30°C) and operating sensitivity is see exact maker revision. A control sensitivity figure must not be confused with measurement resolution. Locate the sensor away from localized heating or drafts.

Variant boundary: This MITRA HT250S RF receiver-based product should not inherit a wired sibling’s low-voltage relay specification or a SMART app’s features. Confirm receiver serial/revision, radio pairing instructions, current maker diagram and boiler terminal scheme before replacement.