General Life ARUNA HT10 RF
ARUNA HT10 RF is a General Life wireless room thermostat. The room unit communicates with a separate RF receiver, which switches compatible equipment through its relay.
Model Identification
Manufacturer: General Life
Series: ARUNA
Model: HT10 RF
Category: Wireless room thermostat
Connection: Radio link to receiver; receiver relay to equipment
Room Thermostat Specifications
Receiver Specifications
Compatibility and Installation
Confirm that the heating or cooling equipment supports the receiver’s on/off relay connection, and follow the exact equipment and thermostat manuals. The RF link replaces the cable between room unit and receiver; the receiver still needs power and an equipment connection. Electrical installation should be performed by a qualified installer.
Source and Revision Notes
The product table reports 0.3°C operating sensitivity, while general hysteresis text describes a 0.5°C default. These are reproduced as separate manufacturer statements and should not be treated as equivalent.
Related Pages
Wireless thermostats · ARUNA series · General Life manufacturer
Official Resources
Technical tables checked against the model-specific manufacturer product page on 11 October 2026. The model-family RF manual explicitly includes ARUNA and this model; its available technical data was also checked.
Official ARUNA HT10 RF Product PageOfficial Model-Family RF User Manual
Official Wireless Catalog
AirAlign is an independent informational resource and is not affiliated with General Life.
ARUNA HT10 RF — receiver and heat source compatibility
Split unit design: The wireless thermostat housing is 85.7mm / 85.7mm / 33.5mm and operates from 3V DC (2 x AAA alkaline batteries), while the relay receiver measures 90mm / 90mm / 25mm and is supplied by 230V (AC). These supplies belong to separate components; plan mains electrical safety and the room-unit’s battery replacement individually.
Boiler switching: The receiver contact’s documented resistive-load capacity is 7A (240VAC – resistive load) 10A (120VAC – resistive load). Compare the boiler controller’s volt-free or powered input and contact wiring. This resistive limit alone does not demonstrate suitability for directly starting a motor or driving an inductive valve load.
Comfort and radio checks: The recorded setpoint span is (5°C) – (30°C); sensitivity is 0.3°C. A fixed sensitivity number is not proof of accuracy in all room conditions. Test pairing through the installed building structure, interference, loss-of-signal operation and safe receiver manual override.
Replacement decision: A visually similar wired or SMART ARUNA HT10 RF sibling may use completely different switching/power hardware. Confirm official model and receiver revision, radio instructions and the heating appliance interface before substitution.