GENERAL LIFE · ROOM THERMOSTAT

General Life SENNA HT301S

SENNA HT301S is a General Life room thermostat. This profile documents the wired version’s published technical data and keeps other manufacturer-listed configurations separate.

Model Identification

Manufacturer: General Life
Series: SENNA
Model: HT301S
Category: Room thermostat

Key Specifications — SENNA HT301S (Wired)

Dimensions (H/L/W)85mm / 125mm / 19mm
Power supply (manufacturer: Operating Current)3V DC (2 x AAA Alkaline Battery)
Relay NO Switching Current2A/30VDC (Resistive Load) 0.5A/125VAC (Resistive Load)
Temperature measurement accuracy (manufacturer-reported)0.1°C
Operating sensitivity (manufacturer-reported)(-2.0°C) – (+2.0°C)
Setpoint range (manufacturer: Operating Temperature Range)(5°C) – (30°C)
Battery Life1 Year (2 x AAA)
Ambient operating temperature(-10°C) – (+50°C)
Storage Temperature(-20°C) – (+60°C)
Specification scope: These values refer to the wired SENNA HT301S only. RF and SMART versions have separate receiver, power and connectivity requirements. The manufacturer’s 0.1°C measurement figure is reproduced as reported; it is not an independently established ±0.1°C accuracy claim. Check the current manual and exact variant before installation.

Related Pages

SENNA series · General Life

Official Resources

Source: General Life’s SENNA HT301S wired product specification. Technical data checked on 11 October 2026.

Official SENNA HT301S Wired Product Page

AirAlign is an independent informational resource.

SENNA HT301S: design-in and commissioning assessment

Package: The manufacturer lists 85mm / 125mm / 19mm (landscape-style wall placement) and a room control supply of 3V DC (2 x AAA Alkaline Battery). Check the cabinet or wall clearance, measuring location and access for its battery before replacing another series.

Electrical contact: The normally-open switching value is 2A/30VDC (Resistive Load) 0.5A/125VAC (Resistive Load) under the stated load condition. Determine the heat-source input type, electrical isolation, permitted cable and inductive-load requirements. A dry-contact relay rating is not blanket permission to drive motors or arbitrary 230 V equipment directly.

Settings: This SENNA HT301S record lists (5°C) – (30°C) for user setpoint adjustment and (-2.0°C) – (+2.0°C) operating sensitivity. Manufacturer control sensitivity is not a verified ±2°C measurement uncertainty. Review setpoint hysteresis, thermal inertia and heating on/off cycle at installation.

Exact model boundary: An RF receiver or connected SMART product under the same series name can have different electrical and connectivity requirements. Use the linked original General Life documentation for the delivered wired configuration.