Products & Manufacturers / Controls & HVAC Equipment / Pressure Switches / LEFOO LF56 Boiler Steam Pressure Controller
LEFOO · BOILER STEAM PRESSURE CONTROLLER

LEFOO LF56 Boiler Steam Pressure Controller

LEFOO LF56 original product photo
LEFOO LF56 · Manufacturer image and specification

OEM-specified LEFOO LF56 boiler steam pressure controller for steam, air, water and other oem-compatible noncorrosive media applications. Selection must match the exact version, operating conditions and signal output.

LF56Pressure SwitchesLEFOO model-specific reference

Model Identification & Specifications

ManufacturerLEFOO
ModelLF56
Device and technologyBoiler steam pressure controller
Process mediumSteam, air, water and other OEM-compatible noncorrosive media
Range and structural limitsLF5615 15–100 kPa; LF5650 35–350 kPa; LF56150 70–1035 kPa; LF56300 140–2070 kPa
Electrical interfaceSPDT contact; full-load and locked-rotor values require model validation
Approval levelModel/suffix evidence to verify
Catalog contextPressure Switches
Safety and scope: Family-wide limits can vary with diaphragm, port, switchpoint band and termination. Neither pressure proof nor burst pressure is a normal adjustment threshold, and manufacturer conformity documents must be matched to the ordered configuration.

Original Manufacturer Technical Information

The LF56 is SPDT boiler/steam pressure controller with noncorrosive oil/water/air/steam media; maker EXCLUDES chlorine-containing liquid. LF5615 15–100kPa operating and 170kPa max diaphragm pressure, LF5650 35–350kPa/590kPa max, LF56150 70–1035kPa/1550kPa max, LF56300 140–2070kPa/2410kPa max. Do not select a high-range model from a low-range diaphragm limit. Ambient −29…66°C, process −40…180°C only non-frozen and maker electrical FL versus LR current ratings need exact load type.

Confirm pressure control versus safety-cutout role, manual reset versus automatic reset, rated pressure/temperature and actual refrigerant or steam medium. Select the correct process port, contacts, mounting enclosure and electrical locked-rotor rating for the compressor or pump. Confirm the correct order code, available model-specific imagery and relevant manufacturer compliance documents. Check manufacturer current order-code evidence before field installation.

Engineering Selection & Practical Interpretation

Each LF56 pressure band has its own diaphragm maximum: 170, 590, 1550 and 2410 kPa respectively. Do not apply the largest diaphragm limit to a low-range controller. Original maker excludes chlorine-containing liquids and requires the media not to freeze.

Before using the switch as a protective device, verify how it responds at trip, reset and loss of supply, and whether a separate calibrated monitor is required. The contact wiring, allowable media and operating temperature must correspond to the original controller design. Select a documented variant instead of assuming that similarly named housings are interchangeable.

Installation and Integration

Function & calibration

Differentiate threshold switching from continuous measurement. Confirm adjustment range, hysteresis, measurement reference and sample setup for the operating medium.

Electrical interface

NO/NC/SPDT contact type and current are configuration-specific. Low-current reed or signal contacts require suitable control electronics rather than direct motor wiring.

Mechanical environment

Check approved media, temperature, fitting, mounting orientation, protection against surges and ingress performance at the supplied cable termination.

Approvals and replacement

Conformity needs the exact serial/part option and certificate scope. A product-family marketing statement is not evidence that another configuration is explosion-protected.

Related Product Models

Related LEFOO model #4505 · Related LEFOO model #4493 · LEFOO manufacturer profile

Official Technical Resources

LEFOO LF56 original manufacturer source

LF56 — steam pressure and independent boiler safety

LF56 is a boiler-steam pressure controller. Process steam temperature, condensate impulse-line handling and approved diaphragm material must be evaluated as well as pressure setpoint and proof rating. Electrical contact control of normal firing is not equivalent to a legally required independent high-pressure limit or relief valve. Verify reset behavior and current certificate/standard of the actual boiler installation before using LF56 in a safety chain.