Products & Manufacturers / Controls & HVAC Equipment / HVAC Controllers / LEFOO TS Capillary Temperature Controller Family
LEFOO · CAPILLARY TEMPERATURE CONTROLLER FAMILY

LEFOO TS Capillary Temperature Controller Family

LEFOO TS is a capillary temperature controller family for bulb temperature. The distinction between a flow, pressure, temperature, protective or remote-actuator contact matters when selecting replacements.

TSHVAC ControllersOriginal maker technical reference

Model Identification & Key Specifications

ManufacturerLEFOO
ModelTS
Device principleCapillary Temperature Controller Family
Measured mediumBulb temperature
Maker operating/configuration envelopeTS30 −30…0°C through TS120 70…120°C options
Output / contactsSPDT; resistive and motor loads have distinct current limits
Page categoryHVAC Controllers
EvidenceSpecific ordering suffix and datasheet needed
Selection scope: Electrical contact ratings, sensing principle, environmental temperature and outlet configuration belong to the ordered version. A model family is not one universal contact or installation class.

Original Manufacturer Data

LEFOO TS is single-bulb SPDT thermal switch control, not a pressure device. Range family TS30 −30…0°C, TS15 −15…15°C, TS40 0…40°C, TS90 40…90°C and TS120 70…120°C; original online table unexpectedly prints T590, whereas maker PDF labels TS90, verify ordered name. OEM direct single-phase motor only below 1kW, otherwise use controller/contactor. SPDT 110VAC non-inductive 20A / 220VAC 10A; inductive full-load 15A / 8A. Temperature capillary sensor and control circuit must be insulated/located properly.

Match the original sensor bulb and mounting, ambient/media operating range, automatic/manual reset circuit, inductive load and exact order code. A thermal trip is not identical to a pressure trip. No independently matched OEM model photo or current exact order-code ATEX/IECEx approval is claimed.

AirAlign Engineering & Variant Comparison

The online maker table includes an apparent T590 / TS90 naming inconsistency. The temperature sensing capillary cannot be replaced by a pressure switch, and direct motor control is limited by the maker’s contact/HP rules—use suitable relay/contactor for larger motors.

Always identify whether the part measures a continuously variable signal, provides a discrete protective trip or controls an operating cycle. Component substitution should preserve sensing topology, switching hysteresis, reset and energized/deenergized states. Enclosure and cable routing must be assessed within the actual equipment, not only against a standalone catalogue illustration.

Installation and Integration Checks

Wiring and load

Check supply voltage, relay versus transistor wiring, contact NO/NC state and peak inductive duty. Signal outputs are not equivalent to motor-control contacts.

Measurement method

Distinguish temperature difference from independent thermal limits, and paddle/piston/calorimetric flow measurement from pressure differential. Match actual calibration media.

Mounting and operating environment

Mount as specified for the device’s reference sensor or mechanical paddle; verify working medium, housing, ingress protection, maximum process temperature and cable/port fittings.

Safety and certificates

Confirm applicable safety function and approvals for the exact order-code revision. CE/UL/TÜV product claims do not establish ATEX/IECEx protection without matching certificate scope.

Related Products

LEFOO TSD · LEFOO LF55T · LEFOO manufacturer profile

Independent AirAlign engineering page. Device-specific maker photo and current exact-variant third-party approvals require separate verification.

TS series — bulb temperature and electrical loads

LEFOO TS capillary controllers include different maker temperature-range families, so a TS30 cold-range control is not mechanically or thermally equivalent to a TS120 warmer-process model. Confirm bulb and capillary length, insertion/thermal contact, switch differential and SPDT terminal assignment for the exact model. Contact ratings vary with motor versus resistive duty and may require an external contactor. A capillary control should not replace an independent certified boiler or refrigeration safety limit without approval.