General Life ILLONA HT25
ILLONA HT25 is a General Life room thermostat. This profile documents the wired version’s published technical data and keeps other manufacturer-listed configurations separate.
Model Identification
Manufacturer: General Life
Series: ILLONA
Model: HT25
Category: Room thermostat
Key Specifications — ILLONA HT25 (Wired)
Related Pages
Official Resources
Source: General Life’s ILLONA HT25 wired product specification. Technical data checked on 11 October 2026.
Official ILLONA HT25 Wired Product PageAirAlign is an independent informational resource.
Application and replacement analysis — ILLONA HT25
Room mounting: The stated 85.7mm / 85.7mm / 33.5mm form factor and 3V DC (2 x AAA Alkaline Battery) power supply define important ILLONA HT25 installation constraints. A wired thermostat can still use batteries; the boiler connection and thermostat’s own supply are distinct. Check mounting depth, wall finish and access for battery changes.
Electrical matching: Contact data 2A/30VDC (Resistive Load) 0.5A/125VAC (Resistive Load) describe a specified resistive load. Obtain the heat source’s control-input diagram to confirm open/close logic, voltage and isolation; motor or pump control cannot be inferred from a low-current thermostat contact rating.
Control settings: The recorded temperature setpoint window is (5°C) – (30°C), with manufacturer sensitivity (-2.0°C) – (+2.0°C). A negative-to-positive adjustment entry should not be advertised as a ±2°C sensor measurement tolerance. Compare this with occupant preferences, heating inertia and switching frequency before commissioning.
Exact configuration: Do not migrate the ILLONA HT25 wired specifications to a similarly named wireless or smart variant; receiver mains supply, connectivity and switch circuitry require separate identification and current General Life technical documents.