Products & Manufacturers / Controls & HVAC Equipment / Pressure Switches / LEFOO LF15 Air Compressor Pressure Switch
LEFOO ยท MECHANICAL AIR-COMPRESSOR PRESSURE SWITCH

LEFOO LF15 Air Compressor Pressure Switch

Mechanical air-compressor pressure switch in the LEFOO LF15 family. The correct operating range, contact wiring and hydraulic or pneumatic installation depend on the ordered variant.

LF15Compressed airMechanical / control engineering

Model Identification & Key Specifications

ManufacturerLEFOO
ModelLF15
Product roleMechanical air-compressor pressure switch
Working mediumCompressed air
Maker-listed setting envelopeAdjustable 0.3โ€“1.2 MPa
Electrical switchingNC; 26 A/120 VAC or 20 A/240 VAC maker listing
Options / family variantsOne, two or four ports; optional manual lever and unloader
Manufacturer technical sourceOriginal model source linked below
OEM specification scope: Published family data must be checked against the exact motor, process medium, selected factory pressure points and delivered model suffix. A structural maximum pressure is never automatically the allowable switching setpoint.

Manufacturer Technical Data

Maker gives adjustable 0.3โ€“1.2 MPa and differential 0.15โ€“0.45 MPa, versus maximum working pressure 1.2 MPa; factory adjustment is customer specified. NC 120VAC 26A or 240VAC 20A, optional manual lever/unloader and one/two/four process ports. Do not infer IP54; OEM LF15 listing specifies IP20, important for exposed compressor installations.

AirAlign Engineering & Selection Analysis

The documented IP20 enclosure needs appropriate protection from water, dirt and access to live terminals. IP54 claims from unrelated LF series do not apply; verify the final compressor panel’s exposure and cable-entry arrangement.

Correct system operation is determined by the restart threshold, stop threshold, motor electrical duty and the available pressure supply. An adjustment range does not imply every combination is approved: compare manufacturer-specified differential, pressure proof, operating medium and fitting. For motor-driven equipment, locked-rotor conditions, overload protection and cycling frequency are separately important even where a contact-current rating is published.

Installation, Compatibility & Protection

Pressure settings

Specify both cut-in and cut-out conditions for the intended equipment, and verify the manufacturer’s permitted hysteresis. Do not use proof or burst pressures as running thresholds.

Contact configuration

NO and NC contacts have different protection and restart behavior. Match the wiring schedule and motor/contactor duty, rather than relying only on voltage and ampere numbers.

Medium and threaded port

Verify actual air versus water compatibility, wetted materials, connection thread standard, sealing method and temperature of the process. The manufacturer variant must support the full application.

Component approval

A maker-hosted CE, TรœV, UL or CSA record may cover only stated models and revisions. It is not equivalent to proof of ATEX/IECEx approval or a finished installation certificate.

LF15 Variant and Application Decision Guide

The manufacturer describes LF15 as a tank-pressure controller for compressed air and non-flammable, non-hazardous, non-corrosive gases. It should not be assumed suitable for combustible gases or an Ex installation. Selection depends on the exact mechanical and electrical ordering options, not just the name LF15.

Maker-specified LF15 family parameterPublished range or optionSelection implication
Pressure adjustment0.3โ€“1.2 MPaChoose the required cut-out within the configured operating class.
Differential0.15โ€“0.45 MPaCheck restart pressure and the compressor duty cycle.
Pressure setting toleranceโ‰ค5% of operating pressure valueDo not treat an adjustment-scale marking as a calibration certificate.
Electrical contactNormally closed; 26 A / 120 VAC or 20 A / 240 VAC (maker listing)Verify motor circuit current, voltage and starting arrangements.
Connection optionsFemale 1-port, male 1-port, female/male 2-port, female 4-portMatch port number, thread and additional gauge/valve needs.
Optional hardwareUnloader valve and manual mode available as optionsCheck whether either is included on the delivered part.
Working temperature / enclosureโˆ’20 to +80 ยฐC; IP20Confirm installation location, moisture/dust exposure and guarding.
Factory-settings caveat: LEFOO lists factory settings as dependent on customer requirements. A nominal adjustment span cannot establish the actual cut-in and cut-out of an uninspected part. Determine operating points from the final configured product and verify with suitable test equipment.

LF15 Installation Checks

Pressure system

Verify maximum permitted receiver pressure, appropriate relief protection, contact circuit ratings and the correct pressure-thread seal and support.

Compressor start behavior

An optional unloader valve can reduce starting load. Check compressor pump-head unloading arrangements rather than assuming every LF15 includes one.

Installation orientation

LEFOO lists vertical and horizontal arrangements; confirm specific drawing and tubing routing before installation.

Approval specificity

The manufacturer lists a CSA LF15 certificate download. Its exact covered model and configuration must be checked; do not infer ATEX/IECEx coverage from a general certificate page.

LF15 vs LF10: Why They Are Not Automatic Substitutes

LF10 offers multiple published PSI operating classes with 20 A / 120 VAC and 12 A / 240 VAC for the base LF10 model, while LF15 has a separately published MPa adjustment/differential envelope and different electrical ratings. Even when the enclosure resembles another family, setpoints, connection ports, unloader behavior and ordering suffix determine interchangeability.

Primary evidence: LEFOO LF15 original technical parameters and drawings; LF10 comparison source.

Related Models & AirAlign Categories

LEFOO LF10-L Air Compressor Switch ยท LEFOO LF17 Heavy-Duty Air Compressor Switch ยท Pressure Switches ยท LEFOO manufacturer profile

Official Manufacturer Sources

Original maker catalogue evidence used for the model values above. Review the latest datasheet, ordering chart and approval scope for the specific suffix.

LEFOO original LF15 technical product reference

LF15 โ€” compressor unloading and electrical contact

LF15 is a mechanical air-compressor pressure switch whose cut-out and restart points determine tank cycling. Verify whether the selected assembly includes an unloader connection and how motor inrush compares with the switch contact/contactor duty. Install appropriate relief/check valves and independent overpressure protection rather than relying on the pressure switch as a relief device. The ordered port threads and electrical cover type must match the compressor assembly.