STS SENSOREN TRANSMITTER SYSTEME · LEVEL MEASUREMENT TRANSMITTERS

STS VL6000 Dual-Output Depth and Temperature Transmitter

Official STS VL5000 photograph used as a family illustration on VL6000 model page; not an exact dual-output VL6000 model photo.
Official STS VL5000 photograph used as a family illustration on VL6000 model page; not an exact dual-output VL6000 model photo.

Submersible level plus temperature transmitter featuring two 4–20 mA channels in specified variants, Kevlar-reinforced suspension cable and STS-listed 20 inches water column to over 1,000 psi measuring spans. Accuracy options ±0.1/0.25% FS, stainless steel or titanium housing. Operating process limits depend on configured transmitter.

Original manufacturer catalog

STS VL6000 model specifications and datasheet →

Certification scope: Any CE/FM labeling applies to the specific manufacturer version. No ATEX or IECEx approval is assumed without a separately identified approved model/certificate schedule.

VL6000 two-output level and temperature scaling

VL6000 is identified as a level-plus-temperature device with two 4–20 mA channels in certain versions. Each channel needs its own receiving PLC input, measurement scale and fault-handling rules; do not combine a height span and temperature span into one analog value. Determine probe pressure range, liquid density and reference strategy for hydrostatic level, then confirm thermal sensor placement and the allowable submerged process temperature independently. Kevlar reinforcement is relevant to suspension and strain protection, but it is not a substitute for correct strain relief. The current picture is an STS VL5000 family illustration, not a certified exact VL6000 order code.