WIKA ยท DIFFERENTIAL PRESSURE TRANSMITTERS

WIKA A2G-500 Differential Pressure Sensor

WIKA A2G-500 โ€” original manufacturer product photograph
Original WIKA manufacturer image for model A2G-500.

Digital HVAC differential pressure sensor for filter monitoring and building automation.

Original manufacturer: WIKA

Ex-proof certification: Not established for this model or family in the documentation reviewed. Do not infer hazardous-area safety from a regular HVAC product.

Official Technical Source

Original manufacturer catalog / model documentation โ†’

AirAlign lists the named model or family. Measurement ranges, communication and enclosure options may vary by exact ordering code; check current manufacturer datasheet before specifying a device.

Verified model variants: Manufacturer documentation lists analog voltage/current, Modbus RTU and LoRaWAN configurations depending on ordering code. A2G-500 is designed for air and non-flammable gases; hazardous-area Ex certification is not claimed. Official WIKA A2G-500 specification and downloads.

A2G-500 โ€” differential-pressure sensor, not an airflow controller

WIKA A2G-500 measures differential, gauge and vacuum pressure in air and non-flammable, non-aggressive gases. Its temperature-compensated piezoresistive pressure measurement is intended for HVAC filter, duct and cleanroom monitoring; the A2G-520 is the separate air-flow-computing model and A2G-540 adds PID control.

TopicOriginal manufacturer detailsImplementation and QA
Technology and accuracyPiezoresistive, WIKA published nominal ยฑ0.5% accuracy for the new A2G-500 familyConfirm whether accuracy is based on full scale or selected range and the test conditions in the specific ordering-code datasheet; no blanket alarm accuracy.
Measuring modesDifferential pressure, positive gauge pressure or vacuum pressure; freely configurable rangeThe same two pneumatic ports require correct direction and range selection; do not report absolute atmospheric pressure.
Electrical/digital variantsAnalogue voltage/current, RS-485 Modbus RTU or LoRaWAN, depending on orderLoRaWAN is an optional radio variant; NFC is used for device configuration and is not a continuous measurement bus.
Installation and mechanicsIP65 enclosure; WIKA app/NFC setup; optional 2-inch TFT colour display and relay outputsA relay-equipped 500 can serve two-point switching; it is not the proportional multi-mode A2G-540 controller.
Hazardous-area and mediaNon-flammable/non-aggressive gases, no OEM Ex certificate confirmed hereKeep refrigerant/combustible gases and explosive atmospheres outside claims pending certified variant.

Reference documents and exact-variant requirements

Only the stated model/family is compared here. Confirm purchase suffix, pressure port type, zero/span procedure, required supply, output signal, environmental enclosure, individual approvals and photos before final equipment selection. Model numbers, URLs and manufacturer links already on this page are preserved.

OEM sources: WIKA A2G-500 current model page ยท WIKA new 500/520/540 model announcement.