LEFOO · DIFFERENTIAL PRESSURE TRANSMITTERS

LEFOO LFM11 Differential Pressure Transmitter

LEFOO LFM11 manufacturer-sourced product image
Official LEFOO LFM11 model image; fitted output/display configuration may vary. Manufacturer model page.

Air differential pressure measurement; see exact range and output options in official model data. This exact model identifier appears in LEFOO’s official download list.

Manufacturer: LEFOO

Manufacturer Technical Data

LEFOO official downloadable datasheet index (find LFM11) →

Consult exact datasheet for range, accuracy, power supply, environmental limits and options. This entry identifies a catalog model, not every option/SKU.

LFM11 air DP and airflow

An air differential-pressure transmitter can measure pressure drop across equipment but does not directly supply volumetric flow without a calibrated flow element or fan/duct correlation. Confirm LFM11’s actual calibrated span and BMS output, then route high/low hoses to the appropriate reference points. Evaluate zero drift, overpressure tolerance and mounting vibration. Do not infer an Ex classification from ordinary HVAC deployment.

LFM11 — model-specific differential-pressure configuration

Selection parameterVerified manufacturer evidence
Pressure ranges±100, ±1,000 or ±10,000 Pa (ordered model).
Accuracy and dynamic response±1% full scale; selectable 0.5, 1, 2 or 4 s response filtering.
Outputs4–20 mA, 0–5 V, 0–10 V or RS485 Modbus RTU according to wiring version.
Environment−10 to +60°C working; air and neutral gases; Ø6.2 mm pressure tubing; manufacturer online table prints protection as P54, so verify IP rating on current datasheet.
Overload5 kPa (LFM116), 10 kPa (LFM110) and 80 kPa (LFM112).

Engineering note: Do not interchange the 2/3/4/5/6-wire connections. The displayed full-scale range and overpressure rating must match the specific variant.

Official LEFOO model specification · examined 26 October 2026.