LEFOO · DIFFERENTIAL PRESSURE TRANSMITTERS

LEFOO LFM52 Differential Pressure Transmitter

LEFOO LFM52 original manufacturer model photograph
LEFOO LFM52: original LEFOO model housing image; fitted range, electronics, display and certified module/options may differ by ordered part code.

Multi-range air differential pressure transmitter with ±100/1000/10000 Pa variants, ±1% FS accuracy, Modbus/RS485 or analog output options.

Manufacturer: LEFOO

Official Documentation

Open manufacturer technical source →

The official material may cover several option codes. Confirm live availability, output configuration, safety marking and exact variant with the manufacturer.

Verified manufacturer model evidence

The original LEFOO LFM52 technical page shows this exact instrument housing. Accuracy and analog/RS485 communication, display, power supply and pressure-range choice depend on the model ordering combination. This HVAC differential-pressure transmitter is designed for measurement in air or neutral gases.

LFM52 — Differential Pressure Transmitter

The regular LFM52 air differential transmitter lists variant pressure spans of ±100, ±1,000 or ±10,000 Pa and approximately ±1% full-scale accuracy. Check actual sensor zero, port reversal and acceptable common-mode pressure before using it for cleanroom or duct flow monitoring. RS485/Modbus and analog selections may differ by ordering suffix. Verify sensor zero, pressure connections and the selected output before installation.

LFM52 — conventional DP transmitter

LFM52’s approximate ±100/1,000/10,000 Pa options and ±1% FS family accuracy must be evaluated at the chosen measurement span. Port routing, field zeroing and tubing moisture protection matter for filter loading or cleanroom monitoring. Check selected analog output or RS485 map before wiring. Select the output, pressure range and wiring that match the actual HVAC application.

Manufacturer technical specifications — LFM52

Measured mediumAir or neutral gases
Differential pressure range±100, ±1,000 or ±10,000 Pa (variant-dependent)
Accuracy±1% FS (manufacturer stated)
Outputs4–20 mA, 0–5 VDC, 0–10 VDC, RS-485/Modbus RTU or combined outputs depending on version
Supply12–30 VDC or 24 VAC ±20% for applicable versions
Operating conditions−20 to +70 °C; IP65

These are model-family values published by LEFOO and are not independent test or safety-certification results. Confirm the precise order code, output, materials and installation requirements for the actual supplied variant. Manufacturer model documentation.