WINSEN · SULFUR DIOXIDE (SO₂) SENSORS

Winsen ZE03-SO₂ Sulfur Dioxide Module

Winsen ZE03 sensor family illustration — exact gas-specific variant may differ
Illustrative manufacturer family image; exact configuration may vary.

SO₂-calibrated ZE03 electrochemical sensor module for combustion and air monitoring instruments.

Manufacturer: Winsen

Technical specifications

Target gasSO₂
Range in ZE03 manual0–20 ppm
Resolution in ZE03 manual0.1 ppm
OutputUART and analog voltage

Manufacturer documentation

Official product information / technical documents →

Verify exact gas configuration, part number, calibration, response, environmental limits and applicable safety certification before equipment design-in. Product data can change between revisions. AirAlign is independent of the listed manufacturer.

ZE03-SO₂ — sulfur dioxide sensor lifetime

ZE03-SO₂ is the sulfur-dioxide electrochemical member of Winsen’s ZE03 platform. Its listed nominal 0–20 ppm range must be paired with SO₂-specific sensitivity, background-gas cross-response and acceptable humidity exposure. A building or industrial monitor needs host error reporting and maintenance scheduling; response deterioration should not be interpreted as permanently clean air. Check the manufacturer manual for the specific data scaling and current sensor-replacement interval before commissioning.

ZE03-SO₂ — sulfur dioxide ppm detection, analog slope and UART — gas-specific selection

The Winsen ZE03 electronics are a shared platform, but the Sulfur dioxide (SO₂) electrochemical cell, calibrated units, interfering gases and analog voltage direction are model-specific.

SpecificationManufacturer evidenceIntegration concern
TargetSO₂ sensor in ZE03 three-electrode electrochemical platformA SO₂ cell is not a standard calibrated H₂S cartridge.
Concentration span0–20 ppm per original ZE03 gas matrixDo not quote higher biogas H₂S spans as sulfur dioxide range.
Response dynamics≤30 s under manufacturer reference matrixSensor element aging and gas line retention may slow installed system.
Amplified analog outputMaker matrix gives increasing approximately 0.6–3 V signal on SO₂ gas variantUnlike O₃/Cl₂ variants that use falling voltage.
Supply / communication5 ±0.1 V DC; <5mA; 3 V TTL UART plus analog voltageUse correct decimal precision and firmware frame for SO₂.
Operating conditions−20 to +50 °C, 15–90%RH noncondensing; nominal 2-year design lifeHumidity and gas solubility require appropriate sampling and maintenance.

Commissioning, cross sensitivity and safety

Sulfur dioxide in stack-adjacent or chemical workspaces may coexist with NO₂, ozone or hydrogen sulfide, which can interfere with electrochemical interpretation. The manufacturer publishes SO₂ amplifier output as an increasing voltage over its gas-specific range, but the exact start/end values and polarity should be confirmed in the shipped calibration document. Use a suitable nonreactive sampling path and validate 4–20mA conversion only if an independent transmitter electronics module is present. Final emergency alarm compliance belongs to the finished detector.

OEM source: Winsen ZE03 family and gas-specific manufacturer documentation. Calibrated gas, output map and regional certificate require precise ordered part documentation.

AirAlign model-specific technical editorial update · 25 October 2026; not a certified finished gas-safety device.