Winsen ZE03-O₃ Ozone Module

Ozone-calibrated ZE03 electrochemical module; intended for OEM toxic-gas monitoring.
Manufacturer: Winsen
Technical specifications
| Target gas | O₃ |
|---|---|
| Range in ZE03 manual | 0–10 ppm |
| Resolution in ZE03 manual | 0.1 ppm |
| Output | UART and analog voltage |
| Calibration | Gas-specific configuration required |
Manufacturer documentation
Official product information / technical documents →
Verify exact gas configuration, part number, calibration, response, environmental limits and applicable safety certification before equipment design-in. Product data can change between revisions. AirAlign is independent of the listed manufacturer.
ZE03-O₃ — oxidant monitoring context
The ZE03 ozone configuration is listed around a 0–10 ppm gas-specific range. Its electrochemical sensitivity, cross-interference and calibration differ from the NO₂ and SO₂ variants; do not copy their serial concentration scaling without checking the model. For indoor ozone exposure or air-treatment equipment, placement near the generation source versus an occupied zone leads to different conclusions. Validate host alarm thresholds, airflow, humidity, maintenance and the exact gas-cell datasheet.
ZE03-O₃ — ozone with inverted voltage output convention — gas-specific selection
The Winsen ZE03 electronics are a shared platform, but the Ozone (O₃) electrochemical cell, calibrated units, interfering gases and analog voltage direction are model-specific.
| Specification | Manufacturer evidence | Integration concern |
|---|---|---|
| Selected gas | Ozone O₃ electrochemical module; not NO₂ despite both being oxidants | Set the correct gas cartridge, calibration standard and display units. |
| Reference span | 0–20 ppm in maker ZE03 multigas matrix | Do not assume 0–100 ppm CO or H₂S scale. |
| Time response | ≤120 s for the O₃ reference configuration | Slow response may affect a fast ozone generator shutdown threshold. |
| Analog signal direction | Manufacturer ZE03 range matrix lists ozone amplifier voltage declining ~2 V toward 0 V with rising concentration | Do not assume output rises as pollutant increases. |
| Power/serial | 5 ±0.1 V, <5 mA; 3 V logic-level UART plus amplified analog signal | Not RS485 Modbus or isolated 4–20mA by default. |
| Operating envelope | −20 to +50 °C, 15–90%RH noncondensing; family about 2 years expected | Strong oxidizer and humidity changes require service and reference checks. |
Commissioning, cross sensitivity and safety
Ozone monitoring may be required near corona discharge generators or indoor disinfection rooms. O₃ sensor output in the ZE03 manufacturer matrix has a decreasing analog polarity; treat zero-volts, cable break and very-high-ozone conditions with explicit fault states, not just an inverted simple linear map. Test cross-interference against other oxidants such as NO₂ and chlorine using actual ozone-cell documentation. A gas-sensing module alone does not certify an ozone-worker exposure alarm.
OEM source: Winsen ZE03 family and gas-specific manufacturer documentation. Calibrated gas, output map and regional certificate require precise ordered part documentation.