Technical specifications
| Target gas | NH₃ |
|---|---|
| Range class | 1,000 ppm |
| Principle | Electrochemical |
| Application | Industrial and agricultural monitoring |
Manufacturer documentation
Official product information / technical documents →
Verify exact gas configuration, part number, calibration, response, environmental limits and applicable safety certification before equipment design-in. Product data can change between revisions. AirAlign is independent of the listed manufacturer.
NH3/CR-1000 — high-range cell, overload and humidity effects
Membrapor’s December 2025 datasheet specifies a 3-electrode electrochemical NH₃ sensor, 0–1,000 ppm nominal range, 2,000 ppm maximum overload, 25 ± 8 nA/ppm signal, and T90 under 35 seconds. The 2,000 ppm figure is not a calibrated extension of the normal measurement span. Its stated resolution is electronics-dependent (below 2 ppm in the manufacturer’s reference conditions).
For agricultural/process NH₃, differentiate intermittent leak detection from continuous high-concentration measurement and validate sensor duty cycle and lifetime under actual conditions. Membrapor lists a −10 to +50 °C, 15–90% RH non-condensing environmental range and warns of humidity transients and cross sensitivity (notably oxidizing gases). Set application-specific zero checks and target-gas calibration; the sensor alone does not provide final instrument certification.
Manufacturer reference: Original model specifications. Check the exact model revision and current technical document.