Products & Manufacturers / Hydrostatic level probe
BD|SENSORS LMK 808
Manufacturer: BD|SENSORS. Products & Manufacturers
Hydrostatic level probe. Values below are manufacturer family specifications; ranges and options differ by ordering code.
Technical specifications
| Measurement principle | Hydrostatic level, ceramic sensor |
|---|---|
| Media | Water and suitable liquid media |
| Measurement range | Depends on probe configuration |
Official technical documentation
Manufacturer technical source / datasheet โ
Source reviewed: 17 October 2026. Exact SKU specifications, certifications and ordering options must be verified before product selection.
LMK 808 โ ceramic hydrostatic submersion
LMK 808 measures liquid level indirectly from hydrostatic pressure using a ceramic sensor. The actual calibration depends on liquid density and installed sensor elevation, while liquid chemistry affects wetted material compatibility. Confirm the probe’s pressure reference method, protective cable length, vent termination and process temperature for the ordered configuration. A submerged sensor photo cannot establish suitable abrasion resistance or a complete hazardous-area approval.
LMK 808 โ detachable ceramic submersible level probe: technical profile and specification boundaries
Original BD|SENSORS catalogue differentiates calibrated pressure ranges, media and approval tiers. A family range and optional certification must not be confused with the ordered device.
| Parameter | Original maker statement | Practical selection note |
|---|---|---|
| Measurement | Hydrostatic immersion pressure converted to liquid height | Level calculation changes with liquid density and atmospheric/headspace pressure. |
| Transducer technology | Ceramic sensor, protected in submersible construction | Review ceramic/seal chemical compatibility before aggressive water or sludge duty. |
| Maintenance concept | Detachable probe/cable system for easier exchange | The underwater detachable joint requires original seals and tested moisture integrity. |
| Electrical protection | Manufacturer highlights integral surge/overvoltage protection | Not a substitute for complete lightning/earthing design in long cables. |
| Cable durability | OEM promotes enhanced protection against damage from rodents | Still inspect cable sheath for tensile load, cutting, abrasion and leaks. |
| Calibration ranges | Hydrostatic spans differ by actual LMK 808 ordering code | Do not infer an accuracy number from another BD LMK series. |
| Environmental suitability | For continuous level monitoring in compatible liquid | Do not declare universal chemical, Ex, drinking-water or abrasive approval. |
Application engineering and commissioning
LMK 808 must be suspended at a known elevation relative to tank zero; the cable must not carry unapproved mechanical load. A vented gauge level probe requires a pressure-equalizing reference path kept dry, often through desiccant and a protected junction box. If the tank is pressurized, differential/headspace compensation may be necessary. Converting pressure to meters without density correction will systematically bias readings when liquid concentration or temperature changes. Maintain the detachable interface and original overvoltage/protection requirements.
Original product range: BD|SENSORS manufacturer specifications and linked model documentation. Review exact current sensor code, output, material and certificates before final purchasing.
AirAlign independent technical editorial enrichment ยท 25 October 2026. These statements are not standalone Ex-area approvals, calibration certificates or proof of active stock.